Sewage Pumps
— FWS-FWC Series
— FGR Series
— FLV Series
FWS-FWC Series
Submersible pumps for sewage
32-40-50FWS / 50FWC: Stainless Steel and Cast Iron submersible wastewater lift pumps particularly suitable for the emptying of basements, garages, cellars and flooded premises.
65-80-100FWC: Cast Iron submersible wastewater lift pumps particularly suitable for pumping industrial sewage, screened waste water and mud in the pumping stations. They can be used also to lift clear and dirty water and rain water.
V versions with Vortex Impeller
M versions with Sigle-channel impellers
Applications
- Acquisition of Hydropompe
- New submersible sewage pumps
- Wastewater lift pumps FWS-FWC
32FWS V 50 Hz
Materials/Constr.design | ||
Vortex impeller | Cast iron EN GJL200 | |
External casing | Stainless steel AISI304 | |
Pump body | Cast iron EN GJL200 | |
Cover | Cast iron EN GJL200 | |
Mechanical seal | motor side | Seal ring |
pump side | Graphite/Alumina | |
Motor shaft | Stainless steel AISI416 | |
Power cable | 10 m H07RN-F type, 3G1 mm² and SCHUKO plug | |
Motor | ||
Constr.design | asynchronous squirrel cage-type oil filled | |
Type | 2 poles; 50 Hz | |
Insulation class | F | |
Protection degree | IP68 | |
Voltage | Single-phase | 230V ±6% built-in overheating protection, float switch as optional |
Limits of use | ||
Maximum liquid temperature | +40 °C | |
pH of pumped liquid | 6 - 10 | |
Liquid density | 1,0 kg/dm³ | |
Maximum immersion depth: | 5 m | |
Min. immersion depth for continuos service | 250 mm | |
Free passage | 30 mm | |
Max. number of starting/hour | 20 | |
Construction options | ||
60 Hz version | ||
Different voltages | ||
Food-grade white oil | ||
Silicon carbide (SiC/SiC) mechanical seal |
40FWS V 50 Hz
Materials/Constr.design | ||
Vortex impeller | Cast iron EN GJL200 | |
External casing | Stainless steel AISI304 | |
Pump body | Cast iron EN GJL200 | |
Cover | Cast iron EN GJL200 | |
Mechanical seal | motor side | Seal ring |
pump side | Graphite/Alumina | |
Motor shaft | Stainless steel AISI416 | |
Power cable | Type | 10 m H07RN-F type |
Single-phase | 3G1mm² with SCHUKO plug (CEE 7/VII) | |
Three-phase | 4G1 mm² | |
Motor | ||
Constr.design | asynchronous squirrel cage-type oil filled | |
Type | 2 poles; 50 Hz | |
Insulation class | F | |
Protection degree | IP68 | |
Voltage | Single-phase | 230 V ±6% built-in overheating protection, float switch as optional |
Three-phase | 230V ±10%, 400V ±10% | |
Limits of use | ||
Maximum liquid temperature | +40 °C | |
pH of pumped liquid | 6 - 10 | |
Liquid density | 1,0 kg/dm³ | |
Maximum immersion depth: | 5 m | |
Min. immersion depth for continuos service | 280 mm | |
Free passage | 20 mm | |
Max. number of starting/hour | 20 | |
Voltage | ||
60 Hz version | ||
Limits of use | ||
Maximum liquid temperature | ||
pH of pumped liquid |
50FWS V 50 Hz
Materials/Constr.design | ||
Vortex impeller | Cast iron EN GJL200 | |
External casing | Stainless steel AISI304 | |
Pump body | Cast iron EN GJL200 | |
Cover | Cast iron EN GJL200 | |
Mechanical seal | motor side | Seal ring |
pump side | Silicon carbide (SiC/SiC) | |
Motor shaft | Stainless steel AISI416 | |
Power cable | Type | 10 m H07RN-F type |
Single-phase | 3G1mm² with SCHUKO plug (CEE 7/VII) | |
Three-phase | 4G1 mm² | |
Motor | ||
Constr.design | asynchronous squirrel cage-type in dry chamber | |
Type | 2 poles; 50 Hz | |
Insulation class | F | |
Protection degree | IP68 | |
Voltage | Single-phase | 230 V ±6% built-in overheating protection, float switch as optional |
Three-phase | 230V ±10%, 400V ±10% | |
Limits of use | ||
Maximum liquid temperature | +40 °C | |
pH of pumped liquid | 6 - 10 | |
Liquid density | 1,0 kg/dm³ | |
Maximum immersion depth: | 5 m | |
Min. immersion depth for continuos service | 375 mm | |
Free passage | 50 mm | |
Max. number of starting/hour | 20 | |
Construction options | ||
60 Hz version | ||
Different voltages | ||
External capacitor with 4G1mm² cable | ||
Food-grade white oil |
50FWC V 50 Hz
Materials/Constr.design | ||
Vortex impeller | Cast iron EN GJL200 | |
External casing | Cast iron EN GJL200 | |
Pump body | Cast iron EN GJL200 | |
Cover | Cast iron EN GJL200 | |
Mechanical seal | Silicon carbide (SiC/SiC) | |
Motor shaft | Stainless steel AISI416 | |
Power cable | Type | 10 m H07RN-F type |
Single-phase | 4G1,5mm², capacitor box and SCHUKO plug (CEE 7/VII) | |
Single-phase 50FWC-V-52-1,6M | 4G1,5mm², capacitor box and SCHUKO plug (CEE 7/VII) | |
Three-phase | 4G1,5mm² | |
Motor | ||
Constr.design | asynchronous squirrel cage-type oil filled | |
Type | 2 poles; 50 Hz | |
Insulation class | F | |
Protection degree | IP68 | |
Voltage | Single-phase | 230V ±6% built-in overheating protection (up to 1,1 kW), float switch as optional |
Three-phase | 230V ±10%, 400V ±10% | |
Limits of use | ||
Maximum liquid temperature | +40 °C | |
pH of pumped liquid | 6 - 10 | |
Liquid density | 1,0 kg/dm³ | |
Maximum immersion depth: | 5 m | |
Min. immersion depth for continuos service | 50FWC-V-52-0,9M/T, 50FWC-V-52-1,1M/T | 353 mm |
50FWC-V-52-1,6M/T | 380 mm | |
Free passage | 50FWC-V-52-0,9M/T, 50FWC-V-52-1,1M/T | 40 mm |
50FWC-V-52-1,6M/T | 50 mm | |
Max. number of starting/hour | 20 | |
Construction options | ||
60 Hz version | ||
Different voltages | ||
Food-grade white oil |
50FWC M 50 Hz
Materials/Constr.design | ||
Vortex impeller | Cast iron EN GJL200 | |
External casing | Cast iron EN GJL200 | |
Pump body | Cast iron EN GJL200 | |
Cover | Cast iron EN GJL200 | |
Mechanical seal | Silicon carbide (SiC/SiC) | |
Motor shaft | Stainless steel AISI416 | |
Power cable | Type | 10 m H07RN-F type |
Single-phase | 4G1,5mm², capacitor box and SCHUKO plug (CEE 7/VII) | |
Three-phase | 4G1,5mm² | |
Motor | ||
Constr.design | asynchronous squirrel cage-type oil filled | |
Type | 4 poles; 50 Hz | |
Insulation class | F | |
Protection degree | IP68 | |
Voltage | Single-phase | 230V ±6% built-in overheating protection (up to 1,1 kW), float switch as optional |
Three-phase | 230V ±10%, 400V ±10% | |
Limits of use | ||
Maximum liquid temperature | 40 °C | |
pH of pumped liquid | 6 - 10 | |
Liquid density | 1,0 kg/dm³ | |
Maximum immersion depth: | 5 m | |
Min. immersion depth for continuos service | 50FWC-V-54-0,75M/T | 353 mm |
50FWC-V-54-1,1M/T | 380 mm | |
Free passage | 50FWC-V-54-0,75M/T | 40 mm |
50FWC-V-54-1,1M/T | 50 mm | |
Max. number of starting/hour | 20 | |
Construction options | ||
60 Hz version | ||
Different voltages | ||
Food-grade white oil |
50FWC V4 50 Hz
Materials/Constr.design | ||
Vortex impeller | Cast iron EN GJL200 | |
External casing | Cast iron EN GJL200 | |
Pump body | Cast iron EN GJL200 | |
Cover | Cast iron EN GJL200 | |
Mechanical seal | Silicon carbide (SiC/SiC) | |
Motor shaft | Stainless steel AISI416 | |
Power cable | Type | 10 m H07RN-F type |
Single-phase | 4G1,5mm², capacitor box and SCHUKO plug (CEE 7/VII) | |
Single-phase 50FWC-V-52-1,6M | 4G1,5mm², capacitor box and SCHUKO plug (CEE 7/VII) | |
Three-phase | 4G1,5mm² | |
Motor | ||
Constr.design | asynchronous squirrel cage-type oil filled | |
Type | 2 poles; 50 Hz | |
Insulation class | F | |
Protection degree | IP68 | |
Voltage | Single-phase | 230V ±6% built-in overheating protection (up to 1,1 kW), float switch as optional |
Three-phase | 230V ±10%, 400V ±10% | |
Limits of use | ||
Maximum liquid temperature | +40 °C | |
pH of pumped liquid | 6 - 10 | |
Liquid density | 1,0 kg/dm³ | |
Maximum immersion depth: | 5 m | |
Min. immersion depth for continuos service | 50FWC-M-52-0,9M/T, 50FWC-M-52-1,1M/T | 353 mm |
50FWC-M-52-1,6M/T, 50FWC-M-52-1,6T-HH | 380 mm | |
Free passage | 50FWC-M-52-0,9M/T, 50FWC-M-52-1,1M/T | 40 mm |
50FWC-M-52-1,6M/T, 50FWC-M-52-1,6T-HH | 50 mm | |
Max. number of starting/hour | 20 | |
Construction options | ||
60 Hz version | ||
Different voltages | ||
Food-grade white oil |
65FWC V 50 Hz
Materials/Constr.design | ||
Vortex impeller | Cast iron EN GJL200 | |
External casing | Cast iron EN GJL200 | |
Pump body | Cast iron EN GJL200 | |
Cover | Cast iron EN GJL200 | |
Mechanical seal | motor side | Seal ring |
pump side | Silicon carbide (SiC/SiC) | |
Motor shaft | Stainless steel AISI420 | |
Power cable | 10 m H07RN-F type, 4G1,5mm² | |
Motor | ||
Constr.design | asynchronous squirrel cage-type oil filled | |
Type | 2 poles; 50 Hz | |
Insulation class | F | |
Protection degree | IP68 | |
Voltage | Three-phase | 230V ±10%, 400V ±10% |
Limits of use | ||
Maximum liquid temperature | +40 °C | |
pH of pumped liquid | 6 - 10 | |
Liquid density | 1,0 kg/dm³ | |
Maximum immersion depth: | 5 m | |
Min. immersion depth for continuos service | 464 mm | |
Free passage | 65 mm | |
Max. number of starting/hour | 20 | |
Construction options | ||
60 Hz version | ||
Different voltages | ||
Food-grade white oil |
65FWC M 50 Hz
Materials/Constr.design | ||
Vortex impeller | Cast iron EN GJL200 | |
External casing | Cast iron EN GJL200 | |
Pump body | Cast iron EN GJL200 | |
Cover | Cast iron EN GJL200 | |
Mechanical seal | motor side | Seal ring |
pump side | Silicon carbide (SiC/SiC) | |
Motor shaft | Stainless steel AISI420 | |
Power cable | 10 m H07RN-F type, 4G1,5mm² | |
Motor | ||
Constr.design | asynchronous squirrel cage-type oil filled | |
Type | 2 poles; 50 Hz | |
Insulation class | F | |
Protection degree | IP68 | |
Voltage | Three-phase | 230V ±10%, 400V ±10% |
Limits of use | ||
Maximum liquid temperature | +40 °C | |
pH of pumped liquid | 6 - 10 | |
Liquid density | 1,0 kg/dm³ | |
Maximum immersion depth: | 5 m | |
Min. immersion depth for continuos service | 445 mm | |
Free passage | 50 mm | |
Max. number of starting/hour | 20 | |
Construction options | ||
60 Hz version | ||
Different voltages | ||
Food-grade white oil |
65FWC V4 50 Hz
Materials/Constr.design | ||
Vortex impeller | Cast iron EN GJL200 | |
External casing | Cast iron EN GJL200 | |
Pump body | Cast iron EN GJL200 | |
Cover | Cast iron EN GJL200 | |
Mechanical seal | Silicon carbide (SiC/SiC) | |
Motor shaft | Stainless steel AISI420 | |
Power cable | Type | 10 m H07RN-F type |
Single-phase | 4G1,5mm², capacitor box and SCHUKO plug (CEE 7/VII) | |
Three-phase | 4G1,5mm² | |
Motor | ||
Constr.design | asynchronous squirrel cage-type oil filled | |
Type | 4 poles; 50 Hz | |
Insulation class | F | |
Protection degree | IP68 | |
Voltage | Single-phase | 230V ±6% built-in overheating protection |
Three-phase | 230V ±10%, 400V ±10% | |
Limits of use | ||
Maximum liquid temperature | +40 °C | |
pH of pumped liquid | 6 - 10 | |
Liquid density | 1,0 kg/dm³ | |
Maximum immersion depth: | 5 m | |
Min. immersion depth for continuos service | 445 mm | |
Free passage | 60 mm | |
Max. number of starting/hour | 20 | |
Construction options | ||
60 Hz version | ||
Different voltages | ||
Food-grade white oil |
80FWC M4 50 Hz
Materials/Constr.design | ||
Single-channel impeller | Cast iron EN GJL400 | |
External casing | Cast iron EN GJL250 | |
Pump body | Cast iron EN GJL250 | |
Cover | Cast iron EN GJL250 | |
Mechanical seal | motor side | Graphite/Alumina |
pump side | Silicon carbide (SiC/SiC) | |
Motor shaft | Stainless steel AISI420 | |
Power cable | Type | 10 m S1RN8-F type |
80FWC-M-54-2,2T, 80FWC-M-54-3,1T | 4G1,5+3x1mm² | |
80FWC-M-54-5,5T | 4G2,5+3x1mm² | |
Motor | ||
Constr.design | asynchronous squirrel cage-type in dry chamber | |
Type | 4 poles; 50 Hz | |
Insulation class | F | |
Protection degree | IP68 | |
Voltage | Three-phase | 400V ±10% |
Probe | Thermal in the winding | |
Conductivity in the oil chamber | ||
Limits of use | ||
Maximum liquid temperature | +40 °C | |
pH of pumped liquid | 6 - 10 | |
Liquid density | 1,0 kg/dm³ | |
Maximum immersion depth: | 5 m | |
Min. immersion depth for continuos service | 517 mm | |
Free passage | 80 mm | |
Max. number of starting/hour | 20 | |
Construction options | ||
60 Hz version | ||
Different voltages |
80FWC V4 50 Hz
Materials/Constr.design | ||
Vortex impeller | Cast iron EN GJL250 | |
External casing | Cast iron EN GJL250 | |
Pump body | Cast iron EN GJL250 | |
Cover | Cast iron EN GJL250 | |
Mechanical seal | motor side | Graphite/Alumina |
pump side | Silicon carbide (SiC/SiC) | |
Motor shaft | Stainless steel AISI420 | |
Power cable | Type | 10 m S1RN8-F type |
80FWC-M-54-2,2T, 80FWC-M-54-3,1T | 4G1,5+3x1mm² | |
80FWC-M-54-5,5T | 4G2,5+3x1mm² | |
Motor | ||
Constr.design | asynchronous squirrel cage-type in dry chamber | |
Type | 4 poles; 50 Hz | |
Insulation class | F | |
Protection degree | IP68 | |
Voltage | Three-phase | 400V ±10% |
Probe | Thermal in the winding | |
Conductivity in the oil chamber | ||
Limits of use | ||
Maximum liquid temperature | +40 °C | |
pH of pumped liquid | 6 - 10 | |
Liquid density | 1,0 kg/dm³ | |
Maximum immersion depth: | 5 m | |
Min. immersion depth for continuos service | 500 mm | |
Free passage | 80 mm | |
Max. number of starting/hour | 20 | |
Construction options | ||
60 Hz version | ||
Different voltages |
100FWC M4 50 Hz
Materials/Constr.design | ||
Single-channel impeller | Cast iron EN GJS400 | |
External casing | Cast iron EN GJL250 | |
Pump body | Cast iron EN GJL250 | |
Cover | Cast iron EN GJL250 | |
Mechanical seal | motor side | Graphite/Alumina |
pump side | Silicon carbide (SiC/SiC) | |
Motor shaft | Stainless steel AISI420 | |
Power cable | Type | 10 m S1RN8-F type |
100FWC-M-54-2,2T, 100FWC-M-54-3,1T | 4G1,5+3x1mm² | |
100FWC-M-54-5,5T | 4G2,5+3x1mm² | |
Motor | ||
Constr.design | asynchronous squirrel cage-type in dry chamber | |
Type | 4 poles; 50 Hz | |
Insulation class | F | |
Protection degree | IP68 | |
Voltage | Three-phase | 400V ±10% |
Probe | Thermal in the winding | |
Conductivity in the oil chamber | ||
Limits of use | ||
Maximum liquid temperature | +40 °C | |
pH of pumped liquid | 6 - 10 | |
Liquid density | 1,0 kg/dm³ | |
Maximum immersion depth: | 5 m | |
Min. immersion depth for continuos service | 517 mm | |
Free passage | 80 mm | |
Max. number of starting/hour | 20 | |
Construction options | ||
60 Hz version | ||
Different voltages |
32FWS V 50 Hz
Pump model | Phase | Q = Delivery | |||||||
l/sec 0 | 0,5 | 1 | 1,5 | 2 | 2,5 | 3 | 3,5 | ||
m³/h 0 | 1,8 | 3,6 | 5,4 | 7,2 | 9 | 10,8 | 12,6 | ||
US gpm 0 | 7,9 | 15,8 | 23,7 | 31,7 | 39,6 | 47,5 | 55,5 | ||
H = Total meters head of water column [m] | |||||||||
32FWS-V-52-0,3 | 1 ~ | 7,6 | 6,9 | 6,3 | 5,5 | 4,6 | 3,5 | 2,5 | 1,2 |
40FWS V 50 Hz
Pump model | Phase | Q = Delivery | |||||||||||
l/sec 0 | 0,5 | 1 | 1,5 | 2 | 2,5 | 3 | 3,5 | 4 | 4,5 | 5 | 5,5 | ||
m³/h 0 | 1,8 | 3,6 | 5,4 | 7,2 | 9 | 10,8 | 12,6 | 14,4 | 16,2 | 18 | 19,8 | ||
US gpm 0 | 7,9 | 15,8 | 23,7 | 31,7 | 39,6 | 47,5 | 55,5 | 63,4 | 71,3 | 79,2 | 87,2 | ||
H = Total meters head of water column [m] | |||||||||||||
40FWS-V-52-0,37 | 1 ~ | 7 | 6,5 | 6 | 5,2 | 4,5 | 3,8 | 3 | 2,1 | ||||
40FWS-V-52-0,6 | 1 ~ | 8,1 | 7,8 | 7,1 | 6,8 | 6,2 | 5,7 | 5 | 4,1 | 3,3 | 2,3 | ||
40FWS-V-52-0,7 | 1 ~ | 9,8 | 9 | 8,7 | 8,1 | 7,5 | 6,8 | 5,9 | 5 | 4,2 | 3,5 | 2,5 | 1,5 |
50FWS V 50 Hz
Pump model | Phase | Q = Delivery | ||||||||||||||
l/sec 0 | 1 | 1,5 | 2 | 2,5 | 3 | 3,5 | 4 | 4,5 | 5 | 6 | 7 | 8 | 9 | 10 | ||
m³/h 0 | 3,6 | 5,4 | 7,2 | 9 | 10,8 | 12,6 | 14,4 | 16,2 | 18 | 21,6 | 25,2 | 28,8 | 32,4 | 36 | ||
US gpm 0 | 15,8 | 23,7 | 31,7 | 39,6 | 47,5 | 55,5 | 63,4 | 71,3 | 79,2 | 92,1 | 110,9 | 126,8 | 142,6 | 158,5 | ||
H = Total meters head of water column [m] | ||||||||||||||||
50FWS-V-52-0,9 | 1 ~ | 11 | 10,3 | 9,9 | 9,4 | 8,9 | 8,5 | 7,9 | 7,4 | 6,8 | 6,2 | 4,9 | 3,7 | 2,3 | 1,2 | |
3 ~ | 11 | 10,3 | 9,9 | 9,4 | 8,9 | 8,5 | 7,9 | 7,4 | 6,8 | 6,2 | 4,9 | 3,7 | 2,3 | 1,2 | ||
50FWS-V-52-1,4 | 1 ~ | 12 | 11,5 | 11,2 | 10,8 | 10,5 | 10,1 | 9,7 | 9,2 | 8,6 | 8 | 6,7 | 5,4 | 4 | 2,7 | 1,3 |
3 ~ | 12 | 11,5 | 11,2 | 10,8 | 10,5 | 10,1 | 9,7 | 9,2 | 8,6 | 8 | 6,7 | 5,4 | 4 | 2,7 | 1,3 |
50FWC V 50 Hz
Pump model | Phase | Q = Delivery | ||||||||||
l/sec 0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | ||
m³/h 0 | 3,6 | 7,2 | 10,8 | 14,4 | 18 | 21,6 | 25,2 | 28,8 | 32,4 | 36 | ||
US gpm 0 | 15,8 | 31,7 | 47,5 | 63,4 | 79,2 | 92,1 | 110,9 | 126,8 | 142,6 | 158,5 | ||
H = Total meters head of water column [m] | ||||||||||||
50FWC-V-52-0,9 | 1 ~ | 12,2 | 11 | 9,8 | 8,5 | 7,4 | 6 | 4,3 | 2,3 | |||
3 ~ | 12,2 | 11 | 9,8 | 8,5 | 7,4 | 6 | 4,3 | 2,3 | ||||
50FWC-V-52-1,1 | 1 ~ | 13 | 12 | 11 | 9,5 | 8,3 | 7 | 5,7 | 4,4 | 3 | 1,6 | |
3 ~ | 13 | 12 | 11 | 9,5 | 8,3 | 7 | 5,7 | 4,4 | 3 | 1,6 | ||
50FWC-V-52-1,6 | 1 ~ | 14 | 12,5 | 11,5 | 10,5 | 9,6 | 8,7 | 7,8 | 6,8 | 5,5 | 4 | 2,1 |
3 ~ | 14 | 12,5 | 11,5 | 10,5 | 9,6 | 8,7 | 7,8 | 6,8 | 5,5 | 4 | 2,1 |
50FWC M 50 Hz
Pump model | Phase | Q = Delivery | |||||||||||||
l/sec 0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 12 | 13 | 14 | ||
m³/h 0 | 3,6 | 7,2 | 10,8 | 14,4 | 18 | 21,6 | 25,2 | 28,8 | 32,4 | 36 | 43,2 | 46,8 | 50,4 | ||
US gpm 0 | 15,8 | 31,7 | 47,5 | 63,4 | 79,2 | 92,1 | 110,9 | 126,8 | 142,6 | 158,5 | 190,2 | 206 | 221,9 | ||
Total meters head of water column [m] | |||||||||||||||
50FWC-M-52-0,9 | 1 ~ | 15,5 | 12,5 | 11 | 9,5 | 8,3 | 7 | 5,6 | 4,1 | 2,5 | |||||
3 ~ | 15,5 | 12,5 | 11 | 9,5 | 8,3 | 7 | 5,6 | 4,1 | 2,5 | ||||||
50FWC-M-52-1,1 | 1 ~ | 17,5 | 15 | 13,5 | 12 | 10,5 | 9,4 | 8 | 6,5 | 5 | 3,4 | 1,7 | |||
3 ~ | 17,5 | 15 | 13,5 | 12 | 10,5 | 9,4 | 8 | 6,5 | 5 | 3,4 | 1,7 | ||||
50FWC-M-52-1,1 | 1 ~ | 19 | 17 | 15,5 | 14 | 13 | 12 | 11 | 10 | 9,4 | 8,6 | 7,7 | 5,8 | 4,2 | 2,5 |
3 ~ | 19 | 17 | 15,5 | 14 | 13 | 12 | 11 | 10 | 9,4 | 8,6 | 7,7 | 5,8 | 4,2 | 2,5 | |
50FWC-M-52-1,1 | 3 ~ HH | 24 | 22 | 20,5 | 19 | 17,5 | 16,5 | 15,2 | 14 | 13 |
50FWC V4 50 Hz
Pump model | Phase | Q = Delivery | |||||||||||
l/sec 0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | ||
m³/h 0 | 3,6 | 7,2 | 10,8 | 14,4 | 18 | 21,6 | 25,2 | 28,8 | 32,4 | 36 | 39,6 | ||
US gpm 0 | 15,8 | 31,7 | 47,5 | 63,4 | 79,2 | 92,1 | 110,9 | 126,8 | 142,6 | 158,5 | 174,3 | ||
H = Total meters head of water column [m] | |||||||||||||
50FWC-V-54-0,75 | 1 ~ | 6,4 | 6,2 | 5,8 | 5,3 | 4,6 | 3,8 | 2,8 | 1,8 | ||||
3 ~ | 6,4 | 6,2 | 5,8 | 5,3 | 4,6 | 3,8 | 2,8 | 1,8 | |||||
50FWC-V-54-1,1 | 1 ~ | 7,4 | 7 | 6,6 | 6,2 | 5,8 | 5,4 | 4,9 | 4,4 | 3,9 | 3,3 | 2,5 | 1,6 |
3 ~ | 7,4 | 7 | 6,6 | 6,2 | 5,8 | 5,4 | 4,9 | 4,4 | 3,9 | 3,3 | 2,5 | 1,6 |
65FWC V 50 Hz
Pump model | Phase | Q = Delivery | ||||||||||
l/sec 0 | 4 | 6 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | ||
m³/h 0 | 14,4 | 21,6 | 28,8 | 32,4 | 36 | 39,6 | 43,2 | 46,8 | 50,4 | 54 | ||
US gpm 0 | 63,4 | 92,1 | 126,8 | 142,6 | 158,5 | 174,3 | 190,2 | 206 | 221,9 | 237,7 | ||
H = Total meters head of water column [m] | ||||||||||||
65FWC-V-52-2,2 | 3 ~ | 16,5 | 12,5 | 10,2 | 9 | 8 | 6,8 | 6 | 5,3 | 3,7 | 2 | 1,5 |
65FWC M 50 Hz
Pump model | Phase | Q = Delivery | ||||||||||||
l/sec 0 | 4 | 6 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 18 | ||
m³/h 0 | 14,4 | 21,6 | 28,8 | 32,4 | 36 | 39,6 | 43,2 | 46,8 | 50,4 | 54 | 57,6 | 64,8 | ||
US gpm 0 | 63,4 | 92,1 | 126,8 | 142,6 | 158,5 | 174,3 | 190,2 | 206 | 221,9 | 237,7 | 253,6 | 285,3 | ||
H = Total meters head of water column [m] | ||||||||||||||
65FWC-M-52-1,6 | 3 ~ | 18,5 | 12,5 | 10,4 | 8,5 | 7,7 | 6,8 | 5,7 | 4,9 | 3,6 | 2,3 | 1 | ||
65FWC-M-52-2,2 | 3 ~ | 24 | 17,8 | 15,3 | 13,2 | 12 | 11,3 | 10,2 | 9,1 | 7,9 | 6,6 | 5,1 | 3,6 | 1 |
65FWC V4 50 Hz
Pump model | Phase | Q = Delivery | ||||||||||
l/sec 0 | 4 | 6 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | ||
m³/h 0 | 14,4 | 21,6 | 28,8 | 32,4 | 36 | 39,6 | 43,2 | 46,8 | 50,4 | 54 | ||
US gpm 0 | 63,4 | 92,1 | 126,8 | 142,6 | 158,5 | 174,3 | 190,2 | 206 | 221,9 | 237,7 | ||
H = Total meters head of water column [m] | ||||||||||||
65FWC-V-54-0,75 | 1 ~ | 6 | 4,7 | 3,8 | 3 | 2 | ||||||
3 ~ | 6 | 4,7 | 3,8 | 3 | 2 | |||||||
65FWC-V-54-1,1 | 1 ~ | 8,2 | 7 | 6,1 | 5 | 4,3 | 3,7 | 3 | 2,2 | 1,2 | ||
3 ~ | 8,2 | 7 | 6,1 | 5 | 4,3 | 3,7 | 3 | 2,2 | 1,2 | |||
65FWC-V-54-1,6 | 3 ~ | 11 | 9,5 | 8,5 | 7,2 | 6,6 | 6,1 | 5,9 | 5,4 | 4,9 | 4 | 2,8 |
80FWC M4 50 Hz
Pump model | Phase | Q = Delivery | ||||||||||||
l/sec 0 | 6 | 10 | 15 | 20 | 25 | 30 | 31,3 | 35 | 38 | 40 | 45 | 47 | ||
m³/h 0 | 21,6 | 36 | 54 | 72 | 90 | 108 | 112,7 | 126 | 136,8 | 144 | 162 | 169,2 | ||
US gpm 0 | 92,1 | 158,5 | 237,7 | 317 | 396,2 | 475,5 | 496,1 | 554,8 | 602,3 | 634 | 713,3 | 745 | ||
H = Total meters head of water column [m] | ||||||||||||||
80FWC-M-54-2,2T | 3 ~ | 10,8 | 8,8 | 7,6 | 6,4 | 5,3 | 3,7 | 2,4 | 2 | |||||
80FWC-M-54-3,1T | 3 ~ | 15,6 | 12,1 | 10,8 | 9,6 | 8,4 | 7,1 | 5,5 | 5,2 | 3,7 | 2 | |||
80FWC-M-54-5,5T | 3 ~ | 19,8 | 16,6 | 15,1 | 13,6 | 12,4 | 11 | 9,6 | 9,2 | 7,9 | 6,6 | 5,2 | 3 | 2 |
80FWC V4 50 Hz
Pump model | Phase | Q = Delivery | |||||||||||||||
l/sec 0 | 6 | 8 | 10 | 12 | 14 | 16 | 18 | 20 | 22 | 24 | 26 | 28 | 30 | 32 | 34 | ||
m³/h 0 | 21,6 | 28,8 | 36 | 43,2 | 50,4 | 57,6 | 64,8 | 72 | 79,2 | 86,4 | 93,6 | 100,8 | 108 | 115,2 | 122,4 | ||
US gpm 0 | 92,1 | 126,8 | 158,5 | 190,2 | 221,9 | 253,6 | 285,3 | 317 | 348,7 | 380,4 | 412,1 | 443,8 | 475,5 | 507,2 | 538,9 | ||
H = Total meters head of water column [m] | |||||||||||||||||
80FWC-V-54-1,6T | 3 ~ | 9 | 7,5 | 6,9 | 6,2 | 5,4 | 4,7 | 3,8 | 3 | 2,2 | |||||||
80FWC-V-54-2,2T | 3 ~ | 10,5 | 8,8 | 8,3 | 7,6 | 6,9 | 6,3 | 5,5 | 4,7 | 3,7 | 2,7 | ||||||
80FWC-V-54-3,1T | 3 ~ | 13 | 11,1 | 10,6 | 9,9 | 9,3 | 8,6 | 7,9 | 7,1 | 6,3 | 5,4 | 4,4 | 3,2 | 2 | |||
80FWC-V-54-5,5T | 3 ~ | 16 | 14,1 | 13,6 | 12,8 | 12,3 | 11,7 | 11 | 10,3 | 9,5 | 8,7 | 7,8 | 6,9 | 5,8 | 4,8 | 3,5 | 2,3 |
100FWC M4 50 Hz
Pump model | Phase | Q = Delivery | ||||||||||||||
l/sec 0 | 8 | 10 | 15 | 20 | 25 | 30 | 35 | 38 | 40 | 42,8 | 45 | 50 | 55 | 59 | ||
m³/h 0 | 28,8 | 36 | 54 | 72 | 90 | 108 | 126 | 136,8 | 144 | 154,1 | 162 | 180 | 198 | 212,4 | ||
US gpm 0 | 126,8 | 158,5 | 237,7 | 317 | 396,2 | 475,5 | 554,8 | 602,3 | 634 | 678,4 | 713,3 | 792,5 | 871,8 | 935,2 | ||
H = Total meters head of water column [m] | ||||||||||||||||
100FWC-M-54-2,2T | 3 ~ | 10,6 | 8,9 | 8,4 | 7,3 | 6,3 | 5,1 | 3,9 | 2,6 | 1,6 | ||||||
100FWC-M-54-3,1T | 3 ~ | 12,7 | 11 | 10,5 | 9,4 | 8,4 | 7,2 | 6 | 4,5 | 3,6 | 3 | 2 | ||||
100FWC-M-54-5,5T | 3 ~ | 19 | 16 | 15,2 | 13,8 | 12,5 | 11,3 | 10,2 | 9,1 | 8,3 | 7,8 | 7,1 | 6,5 | 4,8 | 3 | 1,3 |