Submersibile pumps for professional drainage

40-50 FDP: Submersible electric pumps in cast iron and stainless steel, suitable for draining clear and turbid waters. They can be used as ready-to-use portable pumps both for construction site use, basement wells, and for fixed installations with control panel.

70-80-100-150 FDP: Submersible electric pumps suitable for draining clear and turbid water. Suitable for use on construction sites and for pumping liquids, including abrasive ones. Due to their handling they can be easily transported.

Applications

  • Drainage and dewatering
  • Rainwater Recovery
  • Construction site drainage and dewatering
  • Mining, Quarrying drainage and dewatering
  • Emergency flood water drainage

Related Products

40-50FDP 50 Hz

Materials/Constr.design
Open impeller Cast iron EN GJL200
External casing Aluminium alloy EN AW6060
Pump body Aluminium alloy
Cover Aluminium alloy
Filter Aluminium alloy
Wear plate 40FDP-52-1,0M Stainless steel AISI304
50FDP-52-1,4M, 50FDP-52-1,8M Aluminium alloy with rubber coating
Mechanical seal Silicon carbide (SiC/SiC)
Motor shaft Stainless steel AISI420
Power cable Type 10 m H07RN-F type
Single-phase 40FDP-52-1,0M 4G1,5mm², capacitor box and SCHUKO plug (CEE 7/VII)
Single-phase 50FDP-52-1,4M, 50FDP-52-1,8M 4G2,5mm², capacitor box and SCHUKO plug (CEE 7/VII)
Three-phase 4G1,5mm²
Motor
Constr.design asynchronous squirrel cage-type oil filled
Type 2 poles; 50 Hz
Insulation class F
Protection degree IP68
Voltage Single-phase 230V ±6% built-in overheating protection (up to 1,1 kW), float switch as optional
Three-phase 230V ±10%, 400V ±10%
Limits of use
Maximum liquid temperature + 40°C
pH of pumped liquid 5 - 8
Liquid density 1,0 Kg/dm³
Maximum immersion depth: 5 m
Min. immersion depth for continuos service see “Dimensional drawings”
Free passage 6 mm
Max. number of starting/hour 20

Construction options:

- 60 Hz version

- Different voltages

- Food-grade white oil

40FDP-HH 50Hz

Materials/Constr.design
Double open impeller Cast iron EN GJL200
External casing Aluminium alloy EN AW6060
Pump body Aluminium alloy
Cover Aluminium alloy
Filter Aluminium alloy
Wear plate Stainless steel AISI304
Mechanical seal Silicon carbide (SiC/SiC)
Motor shaft Stainless steel AISI431
Power cable Type 10 m H07RN-F type
Single-phase 4G2,5mm², capacitor box and SCHUKO plug (CEE 7/VII)
Three-phase 4G1,5mm²
Motor
Constr.design asynchronous squirrel cage-type oil filled
Type 2 poles; 50 Hz
Insulation class F
Protection degree IP68
Voltage Single-phase 230V ±6%, float switch as optional
Three-phase 230V ±10%, 400V ±10%
Limits of use
Maximum liquid temperature + 40°C
pH of pumped liquid 5 - 8
Liquid density 1,0 Kg/dm³
Maximum immersion depth: 5 m
Min. immersion depth for continuos service 331 mm
Free passage 6 mm
Max. number of starting/hour 20

Construction options:

- 60 Hz version

- Different voltages

- Food-grade white oil

70/80FDP 50Hz

Materials/Constr.design
Open impeller Martensitic stainless steel
External casing Aluminium alloy
Pump body Aluminium alloy
Cover Aluminium alloy
Filter Stainless steel AISI304
Wear plate Graphite/Alumina
Mechanical seal Silicon carbide (SiC/SiC)
Motor shaft Stainless steel AISI420
Power cable Type 10 m H07RN-F type
Single-phase 70FDP-52-2,2M 4G2,5mm², capacitor box and SCHUKO plug (CEE 7/VII)
Three-phase 80FDP-52-4,1T 4G2,5mm²
Three-phase 4G1,5mm²
Motor
Constr.design asynchronous squirrel cage-type in dry chamber
Type 2 poles; 50 Hz
Insulation class F
Protection degree IP68
Voltage Single-phase 230 V ±6%
Three-phase 230V ±10%, 400V ±10%
Limits of use
Maximum liquid temperature + 40°C
pH of pumped liquid 5 - 8
Liquid density 1,1 Kg/dm³
Maximum immersion depth: 5 m
Min. immersion depth for continuos service 457 mm
Free passage 6 mm
Max. number of starting/hour 20

Construction options:

- 60 Hz version

- Different voltages

- With coating in composite material for wear protection (possible variations of the hydraulic performance)

100FDP 50Hz

Materials/Constr.design
Open impeller High chrome cast iron
External casing Stainless steel AISI304
Pump body Cast iron EN GJL 200 with rubber coating
Cover Cast iron EN GJL250
Filter Stainless steel AISI304
Wear plate Cast iron EN GJL 250 with rubber coating
Mechanical seal motor side Graphite/Alumina
pump side Silicon carbide (SiC/SiC)
Motor shaft Stainless steel AISI431
Power cable Type 20 m S1RN8-F type
Three-phase 100FDP-52-5,5T, 100FDP-52-6,5T 4G2,5+3x1mm²
Three-phase 100FDP-52-8,1T 4G4+3x1mm²
Motor
Constr.design asynchronous squirrel cage-type in dry chamber
Type 2 poles; 50 Hz
Insulation class F
Protection degree IP68
Voltage Three-phase 400V ±10%
Limits of use
Maximum liquid temperature + 40°C
pH of pumped liquid 6 - 10
Liquid density 1,1 Kg/dm³
Maximum immersion depth: 15 m
Min. immersion depth for continuos service 150 mm
Free passage 10 mm
Max. number of starting/hour 15

Construction options:

- 60 Hz version

- Different voltages

- Inner control of the thermal probes in the winding, control sequence and lack of phase (on request)

100/150 FDP-LH/HH 50HZ

Materials/Constr.design
Open impeller High chrome cast iron
External casing Stainless steel AISI304
Pump body Cast iron EN GJL 200 with rubber coating
Cover Cast iron EN GJL250
Filter Stainless steel AISI304
Wear plate Cast iron EN GJL 250 with rubber coating
Mechanical seal motor side Graphite/Alumina
pump side Silicon carbide (SiC/SiC)
Motor shaft Stainless steel AISI431
Power cable 20 m 7G4+2x1,5mm², 07RN-F type
Motor
Constr.design asynchronous squirrel cage-type in dry chamber
Type 2 poles; 50 Hz
Insulation class F
Protection degree IP68
Voltage Three-phase 400V ±10%
Limits of use
Maximum liquid temperature + 40°C
pH of pumped liquid 6 - 10
Liquid density 1,1 Kg/dm³
Maximum immersion depth: 15 m
Min. immersion depth for continuos service 200 mm
Free passage 6 mm
Max. number of starting/hour 10

Construction options:

- 60 Hz version

- Different voltages

- Inner control of the thermal probes in the winding, control sequence and lack of phase (on request)

150FDP 50Hz

Materials/Constr.design
Open impeller Stainless steel AISI304
External casing Aluminium alloy
Pump body Aluminium alloy with rubber coating
Cover Aluminium alloy
Filter Aluminium alloy
Wear plate Stainless steel AISI304 with rubber coating
Mechanical seal motor side Graphite/Alumina
pump side Silicon carbide (SiC/SiC)
Motor shaft Stainless steel AISI431
Power cable 20 m 7G4+2x1,5mm², 07RN-F type
Motor
Constr.design asynchronous squirrel cage-type in dry chamber
Type 2 poles; 50 Hz
Insulation class F
Protection degree IP68
Voltage Three-phase 400V ±10%
Limits of use
Maximum liquid temperature + 40°C
pH of pumped liquid 5 - 8
Liquid density 1,1 Kg/dm³
Maximum immersion depth: 15 m
Min. immersion depth for continuos service 350 mm
Free passage 7 mm
Max. number of starting/hour 10

Construction options:

- 60 Hz version

- Different voltages

 

40-50FDP 50 Hz

Pump model Phase Q = Delivery
l/sek. 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
m³/h 0 3,6 7,2 10,8 14,4 18 21,6 25,2 28,8 32,4 36 39,6 43,2 46,8 50,4 54
US gpm 0 15,8 31,7 47,5 63,4 79,2 92,1 110,9 126,8 142,6 158,5 174,3 190,2 206 221,9 237,7
H = Total meters head of water column [m]
40FDP-52-1,0 1 ~ 18 16,5 15 13,5 11 8 4,5 1
3 ~ 18 16,5 15 13,5 11 8 4,5 1
40FDP-52-1,1 3 ~ 20 18,5 17 15,5 13,5 11 8,5 5
50FDP-52-1,4 1 ~ 14,3 14.1 13,7 13,1 12,5 11,8 11 9,8 8,5 7 6 4,5 2,8
50FDP-52-1,8 1 ~ 16,6 16,3 16,1 15,8 15,1 14,2 14 12,8 11,8 10,2 9 7 5,8 4 2
3 ~ 16,6 16,3 16,1 15,8 15,1 14,2 14 12,8 11,8 10,2 9 7 5,8 4 2
50FDP-52-2,2 3 ~ 18,5 18,5 18,2 17,8 17,5 16,5 16 14,7 13,9 12 10,5 9,1 7,5 5,8 4 2

40DFP HH 50 Hz

Pump model Phase Q = Delivery
l/sek. 0 1 2 3 4 5 6 7
m³/h 0 3,6 7,2 10,8 14,4 18 21,6 25,2
US gpm 0 15,8 31,7 47,5 63,4 79,2 92,1 110,9
H = Total meters head of water column [m]
40FDP-52-1,4 HH 1 ~ 31 27 23 19 14,5 10 5,2
40FDP-52-1,8 HH 1 ~ 32 29,5 26 22 18 13 7,8 2
3 ~ 32 29,5 26 22 18 13 7,8 2

70-80FDP 50 Hz

Pump model Phase Q = Delivery
l/sek. 0 2 4 6 8 10 12 15 20 25 28
m³/h 0 7,2 14,4 21,6 28,8 36 43,2 54 72 90 100,8
US gpm 0 31,7 63,4 92,1 126,8 158,5 190,2 237,7 317 396,2 443,8
H = Total meters head of water column [m]
70FDP-52-2,2 1 ~ 16 15 14 12,8 11,3 9,6 8 5
3 ~ 16 15 14 12,8 11,3 9,6 8 5
70FDP-52-3,5 3 ~ 21 20,5 19,5 18,5 17 15,5 13,5 9,5 4
80FDP-52-4,1 3 ~ 23,3 22,9 22,5 21 20,5 18,5 17,5 15,8 11,5 6,5 3,8

100FDP 50 Hz

Pump model Phase Q = Delivery
l/sek. 0 2,5 5 10 15 20 25 30 35 40 45 50
m³/h 0 9 18 36 54 72 90 100,8 108 144 162 180
US gpm 0 39,6 79,2 158,5 237,7 317 396,2 443,8 475,5 634 713,3 792,5
H = Total meters head of water column [m]
100FDP-52-5,5 LH 3 ~ 18,9 17,5 15,7 13,4 11,3 9,1 7 5,1 2,5
100FDP-52-5,5 HH 3 ~ 30 27,9 26 20,8 14,6 6,3
100FDP-52-6,5 LH 3 ~ 22,4 21,4 20 17,6 15,1 12,7 10,9 8,8 6,6 3
100FDP-52-6,5 HH 3 ~ 35,3 32,3 29,5 23,2 16,7 8,3
100FDP-52-8,1 LH 3 ~ 25,9 24,6 22,9 20,7 18,3 15,9 14,1 12,1 9,7 6,8 3
100FDP-52-8,1 HH 3 ~ 45 40,7 36,6 28,8 20,2 10,1

100/150 FDP-LH/HH 50 Hz

Pump model Phase Q = Delivery
l/sek. 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70
m³/h 0 18 36 54 72 90 100,8 108 144 162 180 198 216 234 252
US gpm 0 79,2 158,5 237,7 317 396,2 443,8 475,5 634 713,3 792,5 871,8 951 1030,3 1109,5
H = Total meters head of water column [m]
150FDP-52-11 LH 3 ~ 30 28,3 26,8 24,8 22,8 21 19,3 17,2 15,3 13 10,7 6,7 3
100FDP-52-11 HH 3 ~ 60 52,8 44,9 35,3 24 10
150FDP-52-15 LH 3 ~ 32 30,6 29,3 27,8 26,4 24,3 22,3 20,3 18,5 16,6 14,8 12,4 10,1 6 2
100FDP-52-15 HH 3 ~ 62 54,6 48,4 42 35,1 25,8 16,4 2,3

150FDP 50 Hz

Pump model Phase Q = Delivery
l/sek. 0 20 25 30 35 40 45 50 60 70 80 90
m³/h 0 72 90 100,8 108 144 162 180 216 252 288 324
US gpm 0 317 396,2 443,8 475,5 634 713,3 792,5 951 1109,5 1268 1426,5
H = Total meters head of water column [m]
150FDP-52-22 3 ~ 35 32 31 29 28 26 24 22 18,5 15 11 5

40-50FDP 50 Hz

Pump model Phase Q = Delivery
l/sek. 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
m³/h 0 3,6 7,2 10,8 14,4 18 21,6 25,2 28,8 32,4 36 39,6 43,2 46,8 50,4 54
US gpm 0 15,8 31,7 47,5 63,4 79,2 92,1 110,9 126,8 142,6 158,5 174,3 190,2 206 221,9 237,7
H = Total meters head of water column [m]
40FDP-52-1,0 1 ~ 18 16,5 15 13,5 11 8 4,5 1
3 ~ 18 16,5 15 13,5 11 8 4,5 1
40FDP-52-1,1 3 ~ 20 18,5 17 15,5 13,5 11 8,5 5
50FDP-52-1,4 1 ~ 14,3 14.1 13,7 13,1 12,5 11,8 11 9,8 8,5 7 6 4,5 2,8
50FDP-52-1,8 1 ~ 16,6 16,3 16,1 15,8 15,1 14,2 14 12,8 11,8 10,2 9 7 5,8 4 2
3 ~ 16,6 16,3 16,1 15,8 15,1 14,2 14 12,8 11,8 10,2 9 7 5,8 4 2
50FDP-52-2,2 3 ~ 18,5 18,5 18,2 17,8 17,5 16,5 16 14,7 13,9 12 10,5 9,1 7,5 5,8 4 2

40DFP HH 50 Hz

Pump model Phase Q = Delivery
l/sek. 0 1 2 3 4 5 6 7
m³/h 0 3,6 7,2 10,8 14,4 18 21,6 25,2
US gpm 0 15,8 31,7 47,5 63,4 79,2 92,1 110,9
H = Total meters head of water column [m]
40FDP-52-1,4 HH 1 ~ 31 27 23 19 14,5 10 5,2
40FDP-52-1,8 HH 1 ~ 32 29,5 26 22 18 13 7,8 2
3 ~ 32 29,5 26 22 18 13 7,8 2

70-80FDP 50 Hz

Pump model Phase Q = Delivery
l/sek. 0 2 4 6 8 10 12 15 20 25 28
m³/h 0 7,2 14,4 21,6 28,8 36 43,2 54 72 90 100,8
US gpm 0 31,7 63,4 92,1 126,8 158,5 190,2 237,7 317 396,2 443,8
H = Total meters head of water column [m]
70FDP-52-2,2 1 ~ 16 15 14 12,8 11,3 9,6 8 5
3 ~ 16 15 14 12,8 11,3 9,6 8 5
70FDP-52-3,5 3 ~ 21 20,5 19,5 18,5 17 15,5 13,5 9,5 4
80FDP-52-4,1 3 ~ 23,3 22,9 22,5 21 20,5 18,5 17,5 15,8 11,5 6,5 3,8

100FDP 50 Hz

Pump model Phase Q = Delivery
l/sek. 0 2,5 5 10 15 20 25 30 35 40 45 50
m³/h 0 9 18 36 54 72 90 100,8 108 144 162 180
US gpm 0 39,6 79,2 158,5 237,7 317 396,2 443,8 475,5 634 713,3 792,5
H = Total meters head of water column [m]
100FDP-52-5,5 LH 3 ~ 18,9 17,5 15,7 13,4 11,3 9,1 7 5,1 2,5
100FDP-52-5,5 HH 3 ~ 30 27,9 26 20,8 14,6 6,3
100FDP-52-6,5 LH 3 ~ 22,4 21,4 20 17,6 15,1 12,7 10,9 8,8 6,6 3
100FDP-52-6,5 HH 3 ~ 35,3 32,3 29,5 23,2 16,7 8,3
100FDP-52-8,1 LH 3 ~ 25,9 24,6 22,9 20,7 18,3 15,9 14,1 12,1 9,7 6,8 3
100FDP-52-8,1 HH 3 ~ 45 40,7 36,6 28,8 20,2 10,1

100/150 FDP-LH/HH 50 Hz

Pump model Phase Q = Delivery
l/sek. 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70
m³/h 0 18 36 54 72 90 100,8 108 144 162 180 198 216 234 252
US gpm 0 79,2 158,5 237,7 317 396,2 443,8 475,5 634 713,3 792,5 871,8 951 1030,3 1109,5
H = Total meters head of water column [m]
150FDP-52-11 LH 3 ~ 30 28,3 26,8 24,8 22,8 21 19,3 17,2 15,3 13 10,7 6,7 3
100FDP-52-11 HH 3 ~ 60 52,8 44,9 35,3 24 10
150FDP-52-15 LH 3 ~ 32 30,6 29,3 27,8 26,4 24,3 22,3 20,3 18,5 16,6 14,8 12,4 10,1 6 2
100FDP-52-15 HH 3 ~ 62 54,6 48,4 42 35,1 25,8 16,4 2,3

150FDP 50 Hz

Pump model Phase Q = Delivery
l/sek. 0 20 25 30 35 40 45 50 60 70 80 90
m³/h 0 72 90 100,8 108 144 162 180 216 252 288 324
US gpm 0 317 396,2 443,8 475,5 634 713,3 792,5 951 1109,5 1268 1426,5
H = Total meters head of water column [m]
150FDP-52-22 3 ~ 35 32 31 29 28 26 24 22 18,5 15 11 5