Skip to main content
Drainage and Wastewater Pumps
Drainage Pumps
—  FDR Series
—  FDP Series

FDP Series

Submersibile pumps for professional drainage

40-50 FDP: Submersible electric pumps in cast iron and stainless steel, suitable for draining clear and turbid waters. They can be used as ready-to-use portable pumps both for construction site use, basement wells, and for fixed installations with control panel.

70-80-100-150 FDP: Submersible electric pumps suitable for draining clear and turbid water. Suitable for use on construction sites and for pumping liquids, including abrasive ones. Due to their handling they can be easily transported.

Applications

  • Drainage and dewatering
  • Rainwater Recovery
  • Construction site drainage and dewatering
  • Mining, Quarrying drainage and dewatering
  • Emergency flood water drainage

40-50FDP 50 Hz

Materials/Constr.design
Open impeller Cast iron EN GJL200
External casing Aluminium alloy EN AW6060
Pump body Aluminium alloy
Cover Aluminium alloy
Filter Aluminium alloy
Wear plate 40FDP-52-1,0M Stainless steel AISI304
50FDP-52-1,4M, 50FDP-52-1,8M Aluminium alloy with rubber coating
Mechanical seal Silicon carbide (SiC/SiC)
Motor shaft Stainless steel AISI420
Power cable Type 10 m H07RN-F type
Single-phase 40FDP-52-1,0M 4G1,5mm², capacitor box and SCHUKO plug (CEE 7/VII)
Single-phase 50FDP-52-1,4M, 50FDP-52-1,8M 4G2,5mm², capacitor box and SCHUKO plug (CEE 7/VII)
Three-phase 4G1,5mm²
Motor
Constr.design asynchronous squirrel cage-type oil filled
Type 2 poles; 50 Hz
Insulation class F
Protection degree IP68
Voltage Single-phase
Three-phase 230V ±10%, 400V ±10%
Limits of use
Maximum liquid temperature + 40°C
pH of pumped liquid 5 - 8
Liquid density 1,0 Kg/dm³
Maximum immersion depth: 5 m
Min. immersion depth for continuos service see “Dimensional drawings”
Free passage 6 mm
Max. number of starting/hour 20

Construction options:

- 60 Hz version

- Different voltages

- Food-grade white oil

40-50FDP 50 Hz

Pump model Phase Q = Delivery
l/sek. 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
m³/h 0 3,6 7,2 10,8 14,4 18 21,6 25,2 28,8 32,4 36 39,6 43,2 46,8 50,4 54
US gpm 0 15,8 31,7 47,5 63,4 79,2 92,1 110,9 126,8 142,6 158,5 174,3 190,2 206 221,9 237,7
H = Total meters head of water column [m]
40FDP-52-1,0 1 ~ 18 16,5 15 13,5 11 8 4,5 1
3 ~ 18 16,5 15 13,5 11 8 4,5 1
40FDP-52-1,1 3 ~ 20 18,5 17 15,5 13,5 11 8,5 5
50FDP-52-1,4 14,3 14,1 13,7 13,1 12,5 11,8 11 9,8 8,5 7 6 4,5 2,8
50FDP-52-1,8 1 ~ 16,6 16,3 16,1 15,8 15,1 14,2 14 12,8 11,8 10,2 9 7 5,8 4 2
3 ~ 16,6 16,3 16,1 15,8 15,1 14,2 14 12,8 11,8 10,2 9 7 5,8 4 2
50FDP-52-2,2 3 ~ 18,5 18,5 18,2 17,8 17,5 16,5 16 14,7 13,9 12 10,5 9,1 7,5 5,8 4 2

40DFP HH 50 Hz

Pump model Phase Q = Delivery
l/sek. 0 1 2 3 4 5 6 7
m³/h 0 3,6 7,2 10,8 14,4 18 21,6 25,2
US gpm 0 15,8 31,7 47,5 63,4 79,2 92,1 110,9
H = Total meters head of water column [m]
40FDP-52-1,4 HH 1 ~ 31 27 23 19 14,5 10 5,2
40FDP-52-1,8 HH 1 ~ 32 29,5 26 22 18 13 7,8 2
3 ~ 32 29,5 26 22 18 13 7,8 2

70-80FDP 50 Hz

Pump model Phase Q = Delivery
l/sek. 0 2 4 6 8 10 12 15 20 25 28
m³/h 0 7,2 14,4 21,6 28,8 36 43,2 54 72 90 100,8
US gpm 0 31,7 63,4 92,1 126,8 158,5 190,2 237,7 317 396,2 443,8
H = Total meters head of water column [m]
70FDP-52-2,2 1 ~ 16 15 14 12,8 11,3 9,6 8 5
3 ~ 16 15 14 12,8 11,3 9,6 8 5
70FDP-52-3,5 3 ~ 21 20,5 19,5 18,5 17 15,5 13,5 9,5 4
80FDP-52-4,1 3 ~ 23,3 22,9 22,5 21 20,5 18,5 17,5 15,8 11,5 6,5 3,8

100FDP 50 Hz

Pump model Phase Q = Delivery
l/sek. 0 2,5 5 10 15 20 25 30 35 40 45 50
m³/h 0 9 18 36 54 72 90 100,8 108 144 162 180
US gpm 0 39,6 79,2 158,5 237,7 317 396,2 443,8 475,5 634 713,3 792,5
H = Total meters head of water column [m]
100FDP-52-5,5 LH 3 ~ 18,9 17,5 15,7 13,4 11,3 9,1 7 5,1 2,5
100FDP-52-5,5 HH 3 ~ 30 27,9 26 20,8 14,6 6,3
100FDP-52-6,5 LH 3 ~ 22,4 21,4 20 17,6 15,1 12,7 10,9 8,8 6,6 3
100FDP-52-6,5 HH 3 ~ 35,3 32,3 29,5 23,2 16,7 8,3
100FDP-52-8,1 LH 3 ~ 25,9 24,6 22,9 20,7 18,3 15,9 14,1 12,1 9,7 6,8 3
100FDP-52-8,1 HH 3 ~ 45 40,7 36,6 28,8 20,2 10,1

100/150 FDP-LH/HH 50 Hz

Pump model Phase Q = Delivery
l/sek. 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70
m³/h 0 18 36 54 72 90 100,8 108 144 162 180 198 216 234 252
US gpm 0 79,2 158,5 237,7 317 396,2 443,8 475,5 634 713,3 792,5 871,8 951 1030,3 1109,5
H = Total meters head of water column [m]
150FDP-52-11 LH 3 ~ 30 28,3 26,8 24,8 22,8 21 19,3 17,2 15,3 13 10,7 6,7 3
100FDP-52-11 HH 3 ~ 60 52,8 44,9 35,3 24 10
150FDP-52-15 LH 3 ~ 32 30,6 29,3 27,8 26,4 24,3 22,3 20,3 18,5 16,6 14,8 12,4 10,1 6 2
100FDP-52-15 HH 3 ~ 62 54,6 48,4 42 35,1 25,8 16,4 2,3

150FDP 50 Hz

Pump model Phase Q = Delivery
l/sek. 0 20 25 30 35 40 45 50 60 70 80 90
m³/h 0 72 90 100,8 108 144 162 180 216 252 288 324
US gpm 0 317 396,2 443,8 475,5 634 713,3 792,5 951 1109,5 1268 1426,5
H = Total meters head of water column [m]
150FDP-52-22 3 ~ 35 32 31 29 28 26 24 22 18,5 15 11 5